Dfi KS210-IMX6 Manual Manual de usuario Pagina 27

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 41
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 26
www.d .com
27
Chapter 4 Ports and Connectors
Chapter 4
Pins Function Pins Function
1
GND
2
GND
3
LVDS1_Out3+
4
LVDS0_Out3+
5
LVDS1_Out3-
6 LVDS0_Out3-
7
GND
8 GND
9
LVDS1_Out2+
10 LVDS0_Out2+
11
LVDS1_Out2-
12 LVDS0_Out2-
13
GND
14 GND
15
LVDS1_Out1+
16 LVDS0_Out1+
17
LVDS1_Out1-
18 LVDS0_Out1-
19
GND
20 GND
21
LVDS1_Out0+
22 LVDS0_Out0+
23
LVDS1_Out0-
24 LVDS0_Out0-
25
GND
26 GND
27
LVDS1_CLK+
28 LVDS0_CLK+
29
LVDS1_CLK-
30 LVDS0_CLK-
31
GND
32 GND
33
TP_INT
34 TP_SCL
35
TP_VDD
36 TP_SDA
37
Backlight Power
38 Dimming
39
Backlight Power
40 Panel Power
The table below illustrates the pin functions of the LVDS LCD Panel connector:
FlexCAN Connector
The CAN controller performs communication in accordance with the BOSCH CAN Protocol Ver-
sion 2.0B Active1 (standard format and extended format). The bit rate can be programmed to
a maximum of 1Mbit/s. To connect the CAN controller module to the FlexCAN connector, it is
necessary to add transceiver hardware.
When communicating in a CAN network, individual message objects are configured. The mes-
sage objects and the identifier masks for the receive filter for the received messages are
stored in the message RAM.
Controller Area Network is a message based protocol designed specifically for automotive ap-
plications but now is also used in other areas such as industrial automation and medical equip-
ment.
FlexCAN
12
9
N.C
N.C
N.C
N.C
N.C
N.C
CAN_LO
CAN_HI
GND